av蜜臀网站-av蜜臀在线网站-av免费-av免费播放一区二区三区-av免费不-av免费不卡国产观看

?

常州市衡正電子儀器有限公司是一家集軟件開發(fā)、制造、銷售、服務(wù)于一體的科技型現(xiàn)代化企業(yè)。
掃描手機(jī)二維碼
掃描微信二維碼
13861223798

新聞中心

NEWS CENTER

網(wǎng)站公告:測(cè)試信息來(lái)自互聯(lián)網(wǎng),若涉及侵權(quán),請(qǐng)聯(lián)系我們刪除! 您當(dāng)前所在位置:首頁(yè) > News > Industry information > 正文返回

Viscometer in the use of the process to be aware of several issues

更新時(shí)間:2017-04-20 10:36:54點(diǎn)擊次數(shù):3890次字號(hào):T|T
Rotational viscometer is widely used in the determination of oil, paint, paint, plastics, food, drugs, adhesives and other dynamic viscosity of the fluid. The instrument is simple, cheap, convenient and practical, and thus popular. In the long process of
Rotational viscometer is widely used in the determination of oil, paint, paint, plastics, food, drugs, adhesives and other dynamic viscosity of the fluid. The instrument is simple, cheap, convenient and practical, and thus popular. In the long process of testing the instrument, we found that many users, especially small and medium-sized enterprise test personnel in the course of the existence of many problems, often we test the performance of the instrument is better than the requirements of national measurement procedures, but the user in the test sample When the data deviation is very large. Now on how to correctly use this type of instrument to obtain accurate and reliable measurement results are as follows.

First of all, a brief introduction to the measurement of the instrument principle:
After the start of the rotary viscometer, it is necessary to first detect the zero position. This operation is normally carried out without the installation of the rotor. Then, the inner cylinder of the radius R2 is coaxially mounted in the outer cylinder of the radius R1, which is filled with viscous fluid, To rotate at a steady speed, successive discs, and then through the hairspring and shaft to drive the inner cylinder that is the rotor rotation, the inner tube that is the role of fluid-based viscous moments, the greater the role of the gossamer to compete with the resulting The greater the torque, so the pointer on the dial indicates the greater the scale. Multiplying the reading by a specific coefficient yields the dynamic viscosity of the liquid.

According to its measurement principle, in order to obtain accurate and reliable measurement data must pay attention to the following points:
First, the performance of the instrument must meet the requirements of the national measurement procedures. In the use of the instrument to carry out periodic testing, if necessary (the instrument used frequently or in a critical state) to conduct an intermediate self-examination to determine its metrological performance, coefficient error within the allowable range, or can not get accurate data.

Second, pay special attention to the measured liquid temperature. Many users ignore this point, that the temperature difference does not matter, our experiments show that: when the temperature deviation of 0.5 ℃, some liquid viscosity value deviation of more than 5%, the temperature deviation of a great impact on viscosity, temperature, viscosity decreased. So pay special attention to the measured liquid temperature is constant in the vicinity of the specified temperature, the best measurement is best not to exceed 0.1 ℃.

Third, the measurement of the container tube selection. For the double cylinder rotary viscometer to carefully read the instrument manual, different rotor cylinder matching the corresponding tube, otherwise the measurement results will be a huge deviation. For a single cylinder rotary viscometer, the principle of the outer radius of the outer tube is infinitely large, the actual measurement requirements of the outer cylinder that is measured the inner diameter of the container is not less than a certain size. For example, the Shanghai Tianping Instrument Factory produced NDJ-1 type rotary viscometer, requires the measurement of beakers or straight barrel with a diameter of not less than 70mm. Experiments show that, especially in the use of a rotor, if the container diameter is too small to cause a larger measurement error.

Fourth, the correct choice of the rotor or adjust the speed, so that the value between 20 to 90 cells.
The instrument uses a dial plus pointer readings, its stability and readings are combined together with 0.5 cells, if the reading is too small as 5 cells near the relative error caused by more than 10%, if you choose the right rotor or speed to make Reading in 50 cells, then the relative error can be reduced to 1%. If the indication is more than 90 cells, so that the hairspring produced by the torque is too large, easy to produce creep, damage hairspring, so be sure to correctly select the rotor and speed.

5, frequency correction. For the nominal frequency of domestic equipment at 50Hz, and China's current power supply frequency is 50Hz, we use the frequency meter to test the variability of less than 0.5%, so the general measurement does not require frequency correction. But for Japan and Europe and some of some instruments, the nominal frequency of 60Hz, must be frequency correction, otherwise it will produce 20% of the error, the correction formula is:
Actual viscosity = indicated viscosity × nominal frequency ÷ actual frequency

Six, the rotor immersed in the depth of the liquid and the impact of bubbles.
Rotational viscometer on the rotor immersed in the depth of the liquid has strict requirements, must be in accordance with the instructions required to operate some of the two-cylinder instrument on the test of the amount of liquid has strict requirements, must be measured with a cylinder. The rotor is immersed in the process of the liquid often with bubbles in the rotor after a period of time most of the floating will disappear, attached to the lower part of the rotor bubbles can not be eliminated, the existence of bubbles will give the measurement data to bring a large deviation, so tilt Slowly immersing the rotor is an effective way.

Seven, the rotor cleaning. The measuring rotor includes the outer cylinder to be clean and free of dirt. It is usually cleaned in time after the measurement, especially after measuring the paint and the adhesive. Pay attention to the cleaning method, you can use the appropriate organic solvent soak, do not use metal tools such as hard scraping, because the rotor surface with a serious scratch will bring the measurement results of the deviation.
(編輯:HengZheng)
0 條評(píng)論
不想登錄?直接點(diǎn)擊發(fā)布即可作為游客留言。

新聞中心列表

公司新聞
行業(yè)資訊

新聞推薦

電子天平使用應(yīng)具備的基本知識(shí)

電子密度天平計(jì)量檢定項(xiàng)目

在日常的周期檢定和常規(guī)的產(chǎn)品質(zhì)量檢查中,一般需要檢定以下幾項(xiàng)內(nèi)容...

JA系列電子天平選購(gòu)應(yīng)該注意哪...

JA系列電子天平對(duì)操作人員的兼容性和對(duì)操作環(huán)境的耐受能力。

如何正確使用FA系列電子天平?

準(zhǔn)備將FA系列電子天平放在穩(wěn)定的工作臺(tái)上,避免振動(dòng),氣流、陽(yáng)光直...

FA系列電子天平使用的注意事項(xiàng)

電子天平如何測(cè)量固體密度

鹵素水分測(cè)定儀操作過(guò)程

聯(lián)系我們

地址:江蘇省常州市鐘樓區(qū)龍城大道2188號(hào)新閘科技園

聯(lián)系人:查小姐
郵編:213000
電話:0519-83263587
傳真:0519-83268313
網(wǎng)址:http://www.propp.cn/

聯(lián)系我們
地址:常州市鐘樓區(qū)龍城大道2188號(hào)新閘科技園10棟313
聯(lián)系人:查小姐
電話:0519-83263587
傳真:0519-83268313
網(wǎng)址:http://www.czhz17.com
關(guān)注衡正
Copyright ? 2017 - 2024 All Rights Reserved 常州市衡正電子儀器有限公司 版權(quán)所有  蘇ICP備17024635號(hào) 技術(shù)支持:冉冉科技 網(wǎng)站地圖 
主站蜘蛛池模板: www国产内插视频| 国产欧美一区二区精品久久久| 欧美做愛坉片| 五月天亚洲图片婷婷| 性色香蕉AV久久久天天网| 污污内射在线观看一区二区少妇| 亚洲AV秘无码一区二区在线| 亚洲精品做爰无码片麻豆| 亚洲国产成人无码av在线| 亚洲精品乱码久久久久久金桔影视| 亚洲国产精品无码久久一线| 网黑料爆料一区二区三区| 欧美金发尤物大战黑人| 欧美精品黄页在线观看视频| 久久精品成人无码A片| 久久久久久久性潮| 国产日本亚洲欧美| 国产乱人伦偷精品视频不卡| 国产女女做受ⅹxx高潮| 国产超高清麻豆精品传媒麻豆精品| 99久久精品免费观看国产| 69国产成人网站| 2025亚洲成高清三区二区二区| 国产精品欧美中文字幕| 国产日本中文久久| 国产偷国产亚洲偷亚洲高| 精品日韩欧美一区二区三区| 久久无码国产精品| 欧美日韩激情一区二区三区| 日韩精品一区二区免费看| 日韩欧美一区二区三区中文精品| 亚洲成av人片在www色猫咪| 亚洲国产美女精品久久久| 亚洲一区二区三区高清在线看| 中出内射颜射骚妇| 亚洲第一永久免费网站| 无码人妻精品一区二区蜜桃百度| 女同桌张开腿让我爽了一夜| 国产内射性高湖| 护士的小嫩嫩好紧好爽电影详情手机在线播放 | 中文亚洲av片在线观看|